Telecom & 5G

Carrier networks
01
Industry challenge

Keep radio and edge sites on a common phase and frequency reference.

FeiLink solution

Use FL6000 as the GNSS-referenced PTP grandmaster and SyncE source. At a compatible edge server, FL2504 receives PTP over its SFP28 ports.

  • PTP and SyncE distribution
  • Clock recovery at the edge server

Data Centers

Cloud & enterprise
02
Industry challenge

Compare events across systems when some hosts use NTP and others use PTP.

FeiLink solution

Serve both protocols from FL6000. Use Clock NMS to inspect its active reference, lock state and alarms when timestamps diverge.

  • A common reference for server logs
  • Visibility into clock-source changes

Power & Utilities

Critical operations
03
Industry challenge

Put substation events on a shared timeline and check the stability of the frequency reference.

FeiLink solution

FL4000 distributes PTP using its IEC 61850 profile. Where the utility needs an independent reference for calibration, DP30-Cs supplies a stable 10 MHz signal.

  • Comparable substation event timestamps
  • Independent frequency calibration

Transportation

Rail, road & ports
04
Industry challenge

Align event records between rail sites and connect station phones to the IP voice network.

FeiLink solution

FL5000 distributes time to station systems over PTP or NTP. For station telephony, an FL8160 gateway fitted with FL-AU-8S connects up to eight analog lines per board.

  • Consistent timestamps across stations
  • Existing analog phones on the IP PBX

Broadcast & Media

Production & distribution
05
Industry challenge

Keep IP production equipment aligned and detect a change of timing source during a live program.

FeiLink solution

Configure FL4000 as a PTP grandmaster using its SMPTE ST 2059-2 profile. Clock NMS shows the active clock source, PTP port status and alarms.

  • A common PTP reference for media endpoints
  • Visibility into loss of clock lock

Financial Services

Transactions & audit
06
Industry challenge

Reconcile transaction and application logs that originate on different systems.

FeiLink solution

FL5000 supplies PTP to timing-aware systems and NTP to conventional servers. Choose its rubidium or OCXO configuration according to the required holdover.

  • Comparable timestamps across log sources
  • Holdover selection matched to site requirements

Industrial Networks

Automation & IIoT
07
Industry challenge

Correlate controller and sensor events with records collected by an edge server.

FeiLink solution

FL4000 provides a common PTP reference. In a compatible PCIe edge server, FL2504 can run as an ordinary clock and provides configurable 1 PPS or 10 MHz timing I/O.

  • Aligned event records across plant systems
  • Timing signals available at the edge server

Reference Architecture

Choose a reference, distribute time to the endpoints, then monitor the clocks. Voice gateways can be added separately where a site also needs telephony.

01 · Reference sourcesGNSS or DP30-CsUse GNSS for time of day. Choose a cesium reference where stable 10 MHz frequency is required.
02 · Synchronization layerFL4000, FL5000 or FL6000Select the time server by endpoint protocol, PTP profile, interfaces and holdover requirement.
03 · Timing endpointsFL2504 or network clientsUse a PCIe timing adapter at compatible edge servers or connect devices through their native timing interfaces.
04 · Clock supervisionClock NMSMonitor FL4000 and FL6000 reference sources, lock status, PTP ports and active alarms.
Deployment principle: select the reference, interfaces, redundancy and holdover capability according to the application environment rather than applying the same architecture to every industry.

Request a solution recommendation

Share the application, required interfaces, accuracy target and deployment environment with the FeiLink engineering team.

Discuss your application