BIPM Resolution 5 sets 20 May 2027 as the effective date for continuous UTC. For networks using FL5000 or FL6000, review the entire time path from the reference source to the application that writes timestamps.
Identify where time information changes form
Document the primary and backup reference inputs, the PTP profiles in use and the NTP clients. A PTP client and an NTP client may interpret time properties in different ways. Record the clock settings and confirm that systems comparing timestamps use the same timescale.
Build a small acceptance test
- Record time properties on representative PTP endpoints and the synchronization status of representative NTP clients.
- Simulate a reference change in a lab or agreed maintenance window. Compare timestamps from servers, switches and applications.
- Record the installed firmware versions. Ask FeiLink technical support whether the specific configuration requires any changes and repeat the same test afterwards.
Technical reference
BIPM Resolution 5: technical actions needed to ensure the continuity of UTC